Influence of optical aberrations on the accuracy of an atomic gravimeter - Systèmes de Référence Temps Espace
Pré-Publication, Document De Travail Année : 2024

Influence of optical aberrations on the accuracy of an atomic gravimeter

Influence des aberrations optiques sur l'exactitude d'un gravimètre atomique

Résumé

We present numerical simulations of the impact of laser beam wavefront aberrations in cold atom interferometers. We demonstrate that to reach accuracy at the mrad level, simulations cannot be based on a description of the retroreflection optics only with low-order Zernike polynomials, as the results will then depend on the decomposition order and the decomposition technique chosen. Moreover, simulations with high-order Zernike polynomials or equivalently high spatial frequency components require the propagation of aberrations to be taken into account, rather than adding them to the ideally propagated beam. Finally, we examine the impact of the parameters of the atomic source and show that the use of delta-kicked atomic cloud would efficiently mitigate the impact of this systematic effect.
Fichier principal
Vignette du fichier
Optica-template.pdf (725.11 Ko) Télécharger le fichier
Origine Fichiers produits par l'(les) auteur(s)
licence

Dates et versions

hal-04725143 , version 1 (08-10-2024)
hal-04725143 , version 2 (09-10-2024)

Licence

Identifiants

Citer

Louis Pagot, Sébastien Merlet, Franck Pereira dos Santos. Influence of optical aberrations on the accuracy of an atomic gravimeter. 2024. ⟨hal-04725143v2⟩