Charge resolution in the isochronous mass spectrometry and the mass of $^{51}$Co - CNRS - Centre national de la recherche scientifique Accéder directement au contenu
Article Dans Une Revue Nucl.Sci.Tech. Année : 2021

Charge resolution in the isochronous mass spectrometry and the mass of $^{51}$Co

Xu Zhou
  • Fonction : Auteur
Meng Wang
Yu-Hu Zhang
  • Fonction : Auteur
Hu-Shan Xu
  • Fonction : Auteur
You-Jin Yuan
  • Fonction : Auteur
Jian-Cheng Yang
  • Fonction : Auteur
Yu. A. Litvinov
  • Fonction : Auteur
S.A. Litvinov
  • Fonction : Auteur
Bo Mei
  • Fonction : Auteur
Xin-Liang Yan
  • Fonction : Auteur
Xing Xu
  • Fonction : Auteur
Peng Shuai
  • Fonction : Auteur
Yuan-Ming Xing
  • Fonction : Auteur
Rui-Jiu Chen
  • Fonction : Auteur
Xiang-Cheng Chen
  • Fonction : Auteur
Chao-Yi Fu
  • Fonction : Auteur
Qi Zeng
  • Fonction : Auteur
Ming-Ze Sun
  • Fonction : Auteur
Hong-Fu Li
  • Fonction : Auteur
Qian Wang
Tong Bao
  • Fonction : Auteur
Min Zhang
  • Fonction : Auteur
Han-Yu Deng
  • Fonction : Auteur
Ming-Zheng Liu
  • Fonction : Auteur
Ting Liao
  • Fonction : Auteur
Jin-Yang Shi
  • Fonction : Auteur
Yu-Nan Song
  • Fonction : Auteur

Résumé

Isochronous mass spectrometry (IMS) of heavy-ion storage rings is a powerful tool for the mass measurements of short-lived nuclei. In IMS experiments, masses are determined through precision measurements of the revolution times of the ions stored in the ring. However, the revolution times cannot be resolved for particles with nearly the same mass-to-charge (m/q) ratios. To overcome this limitation and to extract the accurate revolution times for such pairs of ion species with very close m/q ratios, in our early work on particle identification, we analyzed the amplitudes of the timing signals from the detector based on the emission of secondary electrons. Here, the previous data analysis method is further improved by considering the signal amplitudes, detection efficiencies, and number of stored ions in the ring. A sensitive Z-dependent parameter is introduced in the data analysis, leading to a better resolution of $^{34}$Ar$^{18+}$ and $^{51}$Co$^{27+}$ with $A/Z=17/9$. The mean revolution times of $^{34}$Ar$^{18+}$ and $^{51}$Co$^{27+}$ are deduced, although their time difference is merely 1.8 ps. The uncorrected, overlapped peak of these ions has a full width at half maximum of 7.7 ps. The mass excess of $^{51}$Co was determined to be $-27{,}332(41)$ keV, which is in agreement with the previous value of $-27{,}342(48)$ keV.

Dates et versions

hal-03203651 , version 1 (20-04-2021)

Identifiants

Citer

Xu Zhou, Meng Wang, Yu-Hu Zhang, Hu-Shan Xu, You-Jin Yuan, et al.. Charge resolution in the isochronous mass spectrometry and the mass of $^{51}$Co. Nucl.Sci.Tech., 2021, 32 (4), pp.37. ⟨10.1007/s41365-021-00876-0⟩. ⟨hal-03203651⟩
20 Consultations
0 Téléchargements

Altmetric

Partager

Gmail Facebook X LinkedIn More