Image quality of dual-energy cone-beam CT with total nuclear variation regularization

Lukas Schröder
Simon Rit
Jan-Jakob Sonke

Résumé

Despite the improvements in image quality of cone beam computed tomography (CBCT) scans, application remains limited to patient positioning. In this study, we propose to improve image quality by dual energy (DE) imaging and iterative reconstruction using least squares fitting with total variation (TV) regularization. The generalization of TV called total nuclear variation (TNV) was used to generate DE images. We acquired single energy (SE) and DE scans of an image quality phantom (IQP) and of an anthropomorphic human male phantom (HMP). The DE scans were dual arc acquisitions of 70kV and 130kV with a variable dose partitioning between low energy (LE) and high energy (HE) arcs. To investigate potential benefits from a larger spectral separation between LE and HE, DE scans with an additional 2 mm copper beam filtration in the HE arc were acquired for the IQP. The DE TNV scans were compared to SE scans reconstructed with FDK and iterative TV with varying parameters. The contrast-to-noise ratio (CNR), spatial frequency, and structural similarity (SSIM) were used as image quality metrics. Results showed largely improved image quality for DE TNV over FDK for both phantoms. DE TNV with the highest dose allocation in the LE arm yielded the highest CNR. Compared to SE TV, these DE TNV results had a slightly lower CNR with similar spatial resolution for the IQP. A decrease in the dose allocated to the LE arm improved the spatial resolution with a trade-off against CNR. For the HMP, DE TNV displayed a lower CNR and/or lower spatial resolution depending on the reconstruction parameters. Regarding the SSIM, DE TNV was superior to FDK and SE TV for both phantoms. The additional beam filtration for the IQP led to improved image quality in all metrics, surpassing the SE TV results in CNR and spatial resolution.
Fichier principal
Vignette du fichier
Published paper.pdf (1.3 Mo) Télécharger le fichier
Supplementary material.pdf (1.4 Mo) Télécharger le fichier
Origine : Fichiers produits par l'(les) auteur(s)

Dates et versions

hal-03548732 , version 1 (15-02-2022)

Identifiants

Citer

Lukas Schröder, Uros Stankovic, Simon Rit, Jan-Jakob Sonke. Image quality of dual-energy cone-beam CT with total nuclear variation regularization. Biomedical Physics & Engineering Express, 2022, 8 (2), pp.025012. ⟨10.1088/2057-1976/ac4e2e⟩. ⟨hal-03548732⟩
98 Consultations
70 Téléchargements

Altmetric

Partager

Gmail Facebook X LinkedIn More